A written finding
What the supplied evidence supports, where a constraint occurs, or why the conclusion remains unknown.
One site. One decision.
A scoped assessment using Headroom software for one site and one decision. Start with a short fit discussion; suitable records and a supported question are required.
Written finding within five business days after scope is agreed and the required records are confirmed.
Start with a fit discussion about one site and one decision. The assessment uses company-authorized exports only after scope and handling are agreed. It produces a written finding, not external engineering approval.
What the supplied evidence supports, where a constraint occurs, or why the conclusion remains unknown.
Relevant limits and margins, source references, assumptions and evidence gaps, with separate power, cooling and overall conclusions where applicable.
What to verify, reconcile or revise, together with technical evidence and replay materials appropriate to the agreed assessment.
Pipeline Screens are priced per portfolio. A First Site Evaluation is priced per site, based on scope, complexity and the proposed load. Ongoing quarterly reporting is available by annual agreement. Every engagement is quoted in writing before work begins. Fees are for the assessment, never for a favorable result.
For the initial fit discussion, describe the categories you hold and any known gaps. The detailed checklist below is for the agreed assessment after scoping, not a prerequisite for making an inquiry. Do not upload or email operational records until authorized use, recipients and handling are agreed.
Site and equipment arrangement, existing demand, proposed additional load and evaluation period.
Applicable electrical limits, energy or fuel evidence, reserves and higher-priority commitments.
Air, single-phase liquid or mixed cooling, plus source ownership, units, timing, uncertainty and permission to use the records.
One already-running engine or turbine: exact applicable manufacturer operating points, electrical output and auxiliaries, gas-consumption evidence, delivery rate and finite allocation on a lower-heating-value basis, pressure and fuel quality, protected commitments and permitted operating period. Missing operating points are not filled by interpolation or assumed derating.
One battery: usable starting DC energy, applicable charge/discharge limits and efficiencies, protected energy and supplied interval profiles. One already-running No. 2-D diesel generator: applicable rating, net-output and external-auxiliary profiles, fuel-consumption evidence, isolated closed-return tank inventory, unusable fuel, reserves, uncertainty and baseline protection. Generator and auxiliary profiles are constant within each modeled trajectory; applicable load and battery changes use aligned intervals.
Identify air, single-phase liquid or mixed cooling first. Define the IT boundary, relevant air path, any serial liquid interfaces, shared heat-rejection stage, and baseline and proposal conditions.
Bills alone do not establish spare capacity. Neither do PUE, nameplate ratings or observed peaks alone. PUE is the ratio of facility electricity to IT electricity, not a measurement of available cooling capacity.
Interval averages can hide shorter peaks. Keep native export resolution and the documented time basis; there is no universal 15-minute requirement and no promise of continuous adequacy from averages.
No credentials requested. Headroom does not need equipment-control access. An analyst maps supported exports and reviews supporting documents; arbitrary PDFs and spreadsheets are not automatically converted into a valid assessment.
Download the scope and records checklist. Suitable records may establish support, a constraint, a missing-evidence finding or an unknown result.
One site. One question. An agreed period.
A scoped assessment using Headroom software for one site and one decision. Start with a short fit discussion; suitable records and a supported question are required. Agree scope, written authorization and data handling before sharing records.
Written finding within five business days after scope is agreed and the required records are confirmed.
Review the records checklist and who develops Headroom. No sensitive records are needed for the initial inquiry.
Read-only and export-based. A finding tests a supplied proposal over a stated period. No maximum-MW, safe shorter duration, repeat-cycle, firm-capacity or revenue guarantee is implied. Our capacity examples use synthetic inputs. Separate benchmarks check the processing of published Energy Systems Integration Facility (ESIF) measurements from the National Laboratory of the Rockies (NLR), formerly the National Renewable Energy Laboratory (NREL), including mapping, accounting and reported thermal arithmetic. These checks do not establish available site capacity. Customer validation and external engineering review remain outstanding. Methods and verification